Hospital Elevators

Hospital Elevatorsr

Important! Hospital Elevators should be overhauled by periodical and general elevator maintenance. We believe that Human life is more important and valuable than anything else.

Hospital Elevators

These types of elevators are commonly used in buildings such as hospitals, medical centres, community health care centres and nursing homes.

We take the speciality of hospital environments into full considerations for all our hospital elevators. Elevator solutions designed specifically for hospitals to operate safely, stably, and reliably, with a range of powerful standard functions that ensure optimum performance when patient transport needs are high. With top grade modular computerized control systems our elevators start,brakes and travels smoothly. We endeavour to create a sweet and comfortable movable space for both the hospital and patients.

Dimensions of hospital elevators should be in standards that at least one stretcher bed and one companion may go into. Hospital lift cabins should meet the hygienic rules in terms of health and precautions should be taken towards antibacterial prevention. The interior decoration of hospital elevators, also known as patient elevators, is designed as stainless and the lighting is kept at level that does not disturb the patient. Hospital elevator cabin buttons are on the lower position than the other kinds of elevators and their doors are wider than the other kinds. Precautions for any electricity cut should be taken.

Specifications -Hospital Elevator MR (Motor room above)
Type Persons Rated speed
(m/s)
TR
(m)
OH
(mm)
Pit depth
(mm)
Opening size
OP×OPH(mm)
Car size
CW×CD×CH(mm)
Shaft size
HW×HD(mm)

TKJ1250

16
1.0
1.5
1.75
2.0
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
40 ≤ TR ≤ 90
4300
4400
4500
4600
1500
1600
1600
1700

SO 1100×2100

1200×2300×2300

2200×2850

TKJ1350

18
1.0
1.0
1.5
1.75
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
40 ≤ TR ≤ 90
4400
4500
4600
4700
1500
1600
1600
1700

SO 1100×2100

1300×2300×2300

2300×2850

TKJ1600

21
1.0
1.5
1.75
2.0
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
40 ≤ TR ≤ 90
4400
4500
4600
4700
1500
1600
1600
1700

SO 1300×2100

1400×2400×2300

2400×2950


Specifications - Hospital Elevator MRL (Motor room less)
Type Persons Rated speed
(m/s)
TR
(m)
OH
(mm)
Pit depth
(mm)
Opening size
OP×OPH(mm)
Car size
CW×CD×CH(mm)
Shaft size
HW×HD(mm)

TWJ1250

16
1.0
1.5
1.75
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
4400
4500
4600
1500
1600
1700

SO 1100×2100

1200×2300×2300

2200×2850

TWJ1350

18
>1.0
1.5
1.75
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
4400
4500
4600
1500
1600
1700

SO 1100×2100

1300×2300×2300

2300×2850

TWJ1600

21
1.0
1.5
1.75
TR ≤ 45
25 ≤ TR ≤ 65
35 ≤ TR ≤ 80
4400
4600
4700
1600
1700
1800

SO 1300×2100

1400×2400×2300

2400×2950


Any questions? Please contact us